Generac Commercial Series 130kW Standby Generator (120/208V 3-Phase)(NG) SCAQMD Compliant

Generac Commercial Series 130kW Standby Generator (120/208V 3-Phase)(NG) SCAQMD Compliant
Model: QT13068GNAC
$27,439.00
Factory-Direct
This Item Is Built To Order
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping & 
Tax-Free (Except IL)
 
Free ShippingNo Sales Tax* (Except IL)$27,439.00Buy Now
Sales Tax Extra $27,439.00Visit Site
Factory-Direct
This Item Is Built To Order
Enter your ZIP Code below to see an estimated arrival time of delivery to your home or business.
*We currently CANNOT ship this product to Alaska, California, Connecticut, Hawaii or any destination outside of the United States
Free Freight
Free Freight
  • Product Description
  • Reviews
  • 1
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Grade
Style
Run Watts
122,000
Rated Watts
Surge Watts
122,000
Starting Watts
Fuel
Engine
Features
Features
  • This unit is for sale in MA
  • UL Listed: For safety and certified power ratings
  • NG - Powered Generator
  • Designed for commercial buildings with 120/208V service
  • WILL NOT WORK with LP fuel source
  • Whisper-Test
  • Reduces sound output to 65 dB(A) from 75 dB(A) @ 7 meters
  • Automotive-Style Engine
  • Quiet 6.8L Generac V-10 engine liquid-cooled
  • Aluminum Weather-Protected Enclosure
  • Shelters generator from weather and reduces exterior noise
  • Insulation lowers sound levels by 2-3 decibels
  • Built-In Battery Charger
  • Maintains battery (sold separately) at optimum performance
  • Automatic Safety Shutdown
  • Low oil pressure, high temperature protection
  • Overspeed and/or overcrank protection
  • Requires "RTS Series" Transfer Switch (Sold Separately)
  • WILL NOT WORK W/ "HTS Series" Transfer Switch
Specifications
Engine
Engine Brand
Generac 6.8 L V-10
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
3000 RPM
Low Oil Alert/Shutdown
Yes
Product Specs
Voltage
120/208 Three-Phase
Frequency
60 Hertz
Surge Watts
122000 Watts
Rated Watts
122000 Watts
Fuel Type
Natural Gas
NG Power Capacity
122000 Watts
NG Fuel Consumption @ 50% Load
927 ft³/hr
NG Fuel Consumption @ 100% Load
1786 ft³/hr
LP Fuel Consumption @ 100% Load
19.8 gallons/hr
Rated Amps
423 Amps
Decibel Rating @ 7m
65 Test (75 Run) dbA
Transfer Switch
Automatic (Not Included)
Enclosure
Aluminum
Battery
Not Included (700 CCA)
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Transfer Switch Circuits
Circuit Breaker Size
500 Amps
Overview
Made in USA
Yes
Weight
2699 Pounds
Product Style
Standby Generator
Product Length
116 Inches
Product Width
37 Inches
Product Height
55 Inches
Consumer Warranty
2 Years
Commercial Warranty
2 Years
UPC
696471609769
Grade
Style
Run Watts
122,000
Rated Watts
Surge Watts
122,000
Starting Watts
Fuel
Engine
Features
Features
  • This unit is for sale in MA
  • UL Listed: For safety and certified power ratings
  • NG - Powered Generator
  • Designed for commercial buildings with 120/208V service
  • WILL NOT WORK with LP fuel source
  • Whisper-Test
  • Reduces sound output to 65 dB(A) from 75 dB(A) @ 7 meters
  • Automotive-Style Engine
  • Quiet 6.8L Generac V-10 engine liquid-cooled
  • Aluminum Weather-Protected Enclosure
  • Shelters generator from weather and reduces exterior noise
  • Insulation lowers sound levels by 2-3 decibels
  • Built-In Battery Charger
  • Maintains battery (sold separately) at optimum performance
  • Automatic Safety Shutdown
  • Low oil pressure, high temperature protection
  • Overspeed and/or overcrank protection
  • Requires "RTS Series" Transfer Switch (Sold Separately)
  • WILL NOT WORK W/ "HTS Series" Transfer Switch
Specifications
Engine
Engine Brand
Generac 6.8 L V-10
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
3000 RPM
Low Oil Alert/Shutdown
Yes
Product Specs
Voltage
120/208 Three-Phase
Frequency
60 Hertz
Surge Watts
122000 Watts
Rated Watts
122000 Watts
Fuel Type
Natural Gas
NG Power Capacity
122000 Watts
NG Fuel Consumption @ 50% Load
927 ft³/hr
NG Fuel Consumption @ 100% Load
1786 ft³/hr
LP Fuel Consumption @ 100% Load
19.8 gallons/hr
Rated Amps
423 Amps
Decibel Rating @ 7m
65 Test (75 Run) dbA
Transfer Switch
Automatic (Not Included)
Enclosure
Aluminum
Battery
Not Included (700 CCA)
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Transfer Switch Circuits
Circuit Breaker Size
500 Amps
Overview
Made in USA
Yes
Weight
2699 Pounds
Product Style
Standby Generator
Product Length
116 Inches
Product Width
37 Inches
Product Height
55 Inches
Consumer Warranty
2 Years
Commercial Warranty
2 Years
UPC
696471609769
Product Specs
+
Specifications
Engine
Engine Brand
Generac 6.8 L V-10
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
3000 RPM
Low Oil Alert/Shutdown
Yes
Product Specs
Voltage
120/208 Three-Phase
Frequency
60 Hertz
Surge Watts
122000 Watts
Rated Watts
122000 Watts
Fuel Type
Natural Gas
NG Power Capacity
122000 Watts
NG Fuel Consumption @ 50% Load
927 ft³/hr
NG Fuel Consumption @ 100% Load
1786 ft³/hr
LP Fuel Consumption @ 100% Load
19.8 gallons/hr
Rated Amps
423 Amps
Decibel Rating @ 7m
65 Test (75 Run) dbA
Transfer Switch
Automatic (Not Included)
Enclosure
Aluminum
Battery
Not Included (700 CCA)
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Transfer Switch Circuits
Circuit Breaker Size
500 Amps
Overview
Made in USA
Yes
Weight
2699 Pounds
Product Style
Standby Generator
Product Length
116 Inches
Product Width
37 Inches
Product Height
55 Inches
Consumer Warranty
2 Years
Commercial Warranty
2 Years
UPC
696471609769
Reviews
+
This product has no reviews.
Be the first to voice your opinion on this Generac Commercial product.
Product Q&A
(1)
+
Where is the electric tie in on this generator, and what kind of clearance do we need if this product is gna be inside of a 6 foot brick fence
Rusty Willingham 
from Texas 
February 27, 2012
Read Response +
Answer
The installation drawing on the product page in the spec sheet shows where the electrical tie in is located (Stub Up Area) and the distance from a wall is minimum 5 feet but can vary based on your local code requirements.

Note 2 (Spec Sheet): ALLOW SUFFICIENT ROOM ON ALL SIDE OF THE GENERATOR FOR MAINTENANCE AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT APPLICABLE NFPA37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL, STATE AND LOCAL CODES FOR MINIMUM DISTANCES FROM STRUCTURES.

Spec Sheet
Hide Response -
Recommended Accessories
+
How-To Articles
+
Manuals
+
 
 
×
Generac Commercial Series 130kW Standby Generator (120/208V 3-Phase)(NG) SCAQMD Compliant
+
Reset View

Visit Electric Generators Direct on Facebook
View the Electric Generators Direct Twitter Profile Page
Follow Electric Generators Direct on Pinterest
View Electric Generators Direct YouTube Channel
View Electric Generators Direct on Blog
View Electric Generators Direct Tumbler
View Electric Generators Direct LinkedIn Company Profile