Generac Commercial Series 100kW Standby Generator (120/240V Single-Phase)(NG) SCAQMD Compliant

Generac Commercial Series 100kW Standby Generator (120/240V Single-Phase)(NG) SCAQMD Compliant
Model: QT10068ANAC
$24,499.00
Factory-Direct
This Item Is Built To Order
Factory items ship direct from the manufacturer.
Shipping times vary.
Free Shipping & 
Tax-Free (Except IL)
 
Free ShippingNo Sales Tax* (Except IL)$24,499.00Buy Now
No Sales Tax* (Except CA,GA)$24,999.99Visit Site
Sales Tax Extra $24,499.00Visit Site
Sales Tax Extra $24,499.00Visit Site
Factory-Direct
This Item Is Built To Order
Enter your ZIP Code below to see an estimated arrival time of delivery to your home or business.
*We currently CANNOT ship this product to Alaska, California, Connecticut, Hawaii or any destination outside of the United States
Free Freight
Free Freight
  • Product Description
  • Reviews
  • 2
    Product Q&A
  • Recommended Accessories
  • How-To Articles
  • Manuals
Product Description
+
Grade
Style
Run Watts
89,000
Rated Watts
Surge Watts
89,000
Starting Watts
Fuel
Engine
Features
Features
  • This unit is for sale in MA
  • UL Listed: For safety and certified power ratings
  • NG - Powered Generator
  • Designed for large homes & commercial buildings
  • WILL NOT WORK with LP fuel source
  • Whisper-Test
  • Reduces sound output to 61 dB(A) from 72 dB(A) @ 7 meters
  • Automotive-Style Engine
  • Quiet 6.8L Generac V-10 engine liquid-cooled
  • Aluminum Weather-Protected Enclosure
  • Shelters generator from weather and reduces exterior noise
  • Insulation lowers sound levels by 2-3 decibels
  • Built-In Battery Charger
  • Maintains battery (sold separately) at optimum performance
  • Automatic Safety Shutdown
  • Low oil pressure, high temperature protection
  • Overspeed and/or overcrank protection
  • Requires "RTS Series" Transfer Switch (Sold Separately)
  • WILL NOT WORK W/ "HTS Series" Transfer Switch
Specifications
Engine
Engine Brand
Generac 6.8 L V-10
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
2300 RPM
Low Oil Alert/Shutdown
Yes
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Surge Watts
89000 Watts
Rated Watts
89000 Watts
Fuel Type
Natural Gas
NG Power Capacity
89000 Watts
NG Fuel Consumption @ 50% Load
713 ft³/hr
NG Fuel Consumption @ 100% Load
1260 ft³/hr
LP Fuel Consumption @ 100% Load
13.9 gallons/hr
Rated Amps
371 Amps
Decibel Rating @ 7m
61 Test (72 Run) dbA
Transfer Switch
Automatic (Not Included)
Enclosure
Aluminum
Battery
Not Included (700 CCA)
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Overview
Made in USA
Yes
Weight
2531 Pounds
Product Style
Standby Generator
Product Length
116 Inches
Product Width
37 Inches
Product Height
55 Inches
Consumer Warranty
2 Years
Commercial Warranty
2 Years
UPC
696471610079
Grade
Style
Run Watts
89,000
Rated Watts
Surge Watts
89,000
Starting Watts
Fuel
Engine
Features
Features
  • This unit is for sale in MA
  • UL Listed: For safety and certified power ratings
  • NG - Powered Generator
  • Designed for large homes & commercial buildings
  • WILL NOT WORK with LP fuel source
  • Whisper-Test
  • Reduces sound output to 61 dB(A) from 72 dB(A) @ 7 meters
  • Automotive-Style Engine
  • Quiet 6.8L Generac V-10 engine liquid-cooled
  • Aluminum Weather-Protected Enclosure
  • Shelters generator from weather and reduces exterior noise
  • Insulation lowers sound levels by 2-3 decibels
  • Built-In Battery Charger
  • Maintains battery (sold separately) at optimum performance
  • Automatic Safety Shutdown
  • Low oil pressure, high temperature protection
  • Overspeed and/or overcrank protection
  • Requires "RTS Series" Transfer Switch (Sold Separately)
  • WILL NOT WORK W/ "HTS Series" Transfer Switch
Specifications
Engine
Engine Brand
Generac 6.8 L V-10
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
2300 RPM
Low Oil Alert/Shutdown
Yes
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Surge Watts
89000 Watts
Rated Watts
89000 Watts
Fuel Type
Natural Gas
NG Power Capacity
89000 Watts
NG Fuel Consumption @ 50% Load
713 ft³/hr
NG Fuel Consumption @ 100% Load
1260 ft³/hr
LP Fuel Consumption @ 100% Load
13.9 gallons/hr
Rated Amps
371 Amps
Decibel Rating @ 7m
61 Test (72 Run) dbA
Transfer Switch
Automatic (Not Included)
Enclosure
Aluminum
Battery
Not Included (700 CCA)
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Overview
Made in USA
Yes
Weight
2531 Pounds
Product Style
Standby Generator
Product Length
116 Inches
Product Width
37 Inches
Product Height
55 Inches
Consumer Warranty
2 Years
Commercial Warranty
2 Years
UPC
696471610079
Product Specs
+
Specifications
Engine
Engine Brand
Generac 6.8 L V-10
Consumer Engine Warranty
2 Years
Commercial Engine Warranty
2 Years
Engine RPM
2300 RPM
Low Oil Alert/Shutdown
Yes
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Surge Watts
89000 Watts
Rated Watts
89000 Watts
Fuel Type
Natural Gas
NG Power Capacity
89000 Watts
NG Fuel Consumption @ 50% Load
713 ft³/hr
NG Fuel Consumption @ 100% Load
1260 ft³/hr
LP Fuel Consumption @ 100% Load
13.9 gallons/hr
Rated Amps
371 Amps
Decibel Rating @ 7m
61 Test (72 Run) dbA
Transfer Switch
Automatic (Not Included)
Enclosure
Aluminum
Battery
Not Included (700 CCA)
Mounting Pad
Concrete (Not Included)
Cooling System
Liquid Cooled
UL Listed
Yes
Grade Type
Emergency
Overview
Made in USA
Yes
Weight
2531 Pounds
Product Style
Standby Generator
Product Length
116 Inches
Product Width
37 Inches
Product Height
55 Inches
Consumer Warranty
2 Years
Commercial Warranty
2 Years
UPC
696471610079
Reviews
+
This product has no reviews.
Be the first to voice your opinion on this Generac Commercial product.
Product Q&A
(2)
+
What is the minimum gas pressure that the unit will operate at? My supplier says the pressure can drop as low as 3 psi during cold weather. Will that be sufficient?
Andy Weir 
from Maryland 
April 29, 2014
Read Response +
Answer
Per the specification sheet the Operating Fuel Pressure needs to be between 11 - 14 Water Column (0.396 to 0.504 PSI). 3 PSI is more then enough for the generator to operate.

However, depending on the fuel type the requirements can vary. If you hare going to be using LP then the important thing will be the BTU/HR output from the LP tank as this can drop drastically when temperatures drop.

The 100kW unit requires 1,261,425 BTU/HR at start-up so the supplying tank must output this capacity otherwise the generator will not start.

If you are operating on natural gas then the issue is not related and as long as you have the proper PSI you will be ok.

Specification Sheet
Hide Response -
Could you give me the specs for the concrete installation pad? Should the electrical conduit line come right in the center of the pad?
Carlos 
from Maryland 
July 07, 2012
Read Response +
Answer
On the product page you can find the installation drawing in the manufactures spec sheet found under the specs link which shows dimensions and electrical connections.

Spec Sheet
Hide Response -
Recommended Accessories
+
How-To Articles
+
Manuals
+
 
 
×
Generac Commercial Series 100kW Standby Generator (120/240V Single-Phase)(NG) SCAQMD Compliant
+
Reset View

Visit Electric Generators Direct on Facebook
View the Electric Generators Direct Twitter Profile Page
Follow Electric Generators Direct on Pinterest
View Electric Generators Direct YouTube Channel
View Electric Generators Direct on Blog
View Electric Generators Direct Tumbler
View Electric Generators Direct LinkedIn Company Profile