Product Description
+
Type
Manual
Amp Rating
NEMA L14-30R
Circuits
10
Enclosure
NEMA 1R
Type
Manual
Amp Rating
30
Circuits
10
?>
Enclosure
NEMA 1R
Features
Features
  • Safest Way to Distribute Power
  • Eliminates dangerous backfeeds and electrical overloads
  • Prewired Manual Transfer Kit For 6-10 Circuits w/ Metal Conduit
  • Works with any portable generator up to 7500 watts
  • Built-in Wattage Meter
  • Track power input to ensure proper load balancing
  • Requires Power Inlet Box & Cord For Connection (Sold Separately)
  • Allows you to plug your generator into an exterior wall outlet
  • 6 Total Circuits (Expandable to 10)
  • (2) 15-Amp 1-Pole
  • (2) 20-Amp 1-Pole
  • (1) 20-Amp 2-Pole
  • PLEASE NOTE - Requires 2-Pole 60-Amp Breaker in Main Load Center
  • 60-Amp Breaker Sold Separately
Specifications
Plugs
NEMA L14-30R
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Rated Watts
7500 Watts
Rated Amps
30 Amps
Enclosure
NEMA 1R
Number of Circuit Breakers
10
Max Generator Input
30 Amps
Maximum Wattage
7500 Watts
UL Listed
Yes
Transfer Switch Circuits
15A 120V
2
20A 120V
2
20A 240V
1
Plugs
NEMA L14-30R
1
Overview
Made in USA
Yes
Weight
13 Pounds
Product Length
9.25 Inches
Product Width
11.25 Inches
Product Height
3.375 Inches
Consumer Warranty
2 Years
UPC
696471063769
Type
Manual
Amp Rating
NEMA L14-30R
Circuits
10
Enclosure
NEMA 1R
Type
Manual
Amp Rating
30
Circuits
10
?>
Enclosure
NEMA 1R
Features
Features
  • Safest Way to Distribute Power
  • Eliminates dangerous backfeeds and electrical overloads
  • Prewired Manual Transfer Kit For 6-10 Circuits w/ Metal Conduit
  • Works with any portable generator up to 7500 watts
  • Built-in Wattage Meter
  • Track power input to ensure proper load balancing
  • Requires Power Inlet Box & Cord For Connection (Sold Separately)
  • Allows you to plug your generator into an exterior wall outlet
  • 6 Total Circuits (Expandable to 10)
  • (2) 15-Amp 1-Pole
  • (2) 20-Amp 1-Pole
  • (1) 20-Amp 2-Pole
  • PLEASE NOTE - Requires 2-Pole 60-Amp Breaker in Main Load Center
  • 60-Amp Breaker Sold Separately
Specifications
Plugs
NEMA L14-30R
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Rated Watts
7500 Watts
Rated Amps
30 Amps
Enclosure
NEMA 1R
Number of Circuit Breakers
10
Max Generator Input
30 Amps
Maximum Wattage
7500 Watts
UL Listed
Yes
Transfer Switch Circuits
15A 120V
2
20A 120V
2
20A 240V
1
Plugs
NEMA L14-30R
1
Overview
Made in USA
Yes
Weight
13 Pounds
Product Length
9.25 Inches
Product Width
11.25 Inches
Product Height
3.375 Inches
Consumer Warranty
2 Years
UPC
696471063769
Product Specs
+
Specifications
Plugs
NEMA L14-30R
Product Specs
Voltage
120/240 Single-Phase
Frequency
60 Hertz
Rated Watts
7500 Watts
Rated Amps
30 Amps
Enclosure
NEMA 1R
Number of Circuit Breakers
10
Max Generator Input
30 Amps
Maximum Wattage
7500 Watts
UL Listed
Yes
Transfer Switch Circuits
15A 120V
2
20A 120V
2
20A 240V
1
Plugs
NEMA L14-30R
1
Overview
Made in USA
Yes
Weight
13 Pounds
Product Length
9.25 Inches
Product Width
11.25 Inches
Product Height
3.375 Inches
Consumer Warranty
2 Years
UPC
696471063769
Reviews
(3)
+
Generac 6376 Reviews & Ratings
Product Q&A
(3)
+
Search Product Q&A's Answered by Jared, the Generator Expert
icon-social-fb1
+
Can one of the double-pole 20amp breakers, be replaced with a 30amp double pole to power a water heater? I think the answer is yes but cannot tell for sure.
Jeff Eichman 
from Pennsylvania 
April 10, 2014
Answer
Per the installation guide the circuit breaker assortment can be modified to suit specific requirements and does not void the UL listing.

Note: The installer is responsible for providing appropriately sized wires for each circuit.

Owner's Manual / Installation Guide
+
Ref: 30216A As an electrical contractor we have use arc fault circuit breakers on certain loads. This creates a problem with the neutrals. Is there an alternate panel I could use? Thank, Keith
Keith Budka 
from New York 
January 01, 2014
Answer
The following switches accommodate GFCI and ARCH Fault circuit breakers to meet the latest NEC requirements.....

Model 6376

Model 6294

Model 6295

Model 6378

Model 6408

Model 6379
+
Are the breakers in this switch interchangeable with ones that I can pick up at Lowes? Are there knockouts to add the additional 4 circuits? Where? Is there any advantage of having individual transfer switches (like the reliance controls brand) over the 60A interlocked type like on the Generac 6376? Thanks!
Jeff Breneman 
from Ohio 
September 10, 2013
Answer
Thank you for your inquiry!

The breakers that are fitted into the Generac 6376 are the 1" single and double pole breakers. There are many different styles that are listed in detail within the owner's manual. We have provided a link to this manual for your convenience. These are available at many home improvement stores.

Owner's Manual

There are no additional knock-outs for extra circuits. The 4 extra spaces can be accommodated by exchanging your 2-pole breakers for 1-pole models.

The benefit of this style switch is that it will not only function as a transfer mechanism, but also a sub-panel. This adds versatility to any installation.
Recommended Accessories
+
Expert Recommended Accessories Hand Picked By Our Expert Jared
icon-social-fb1
Required Accessories Add All Required
Optional Accessories
How-To Articles
+
Manuals
+
 
 
×
Generac 6376 - 30-Amp Prewired Indoor Manual Transfer Switch (6-10 Circuits)
Generac 6376
+
Reset View
×
Customer Review Images

Visit Electric Generators Direct on Facebook
View the Electric Generators Direct Twitter Profile Page
Follow Electric Generators Direct on Pinterest
View Electric Generators Direct YouTube Channel
View Electric Generators Direct Tumbler
View Electric Generators Direct LinkedIn Company Profile